RAM Structural System CONNECT Edition Update 4 patch 3

Description

RAM Structural System CONNECT Edition Update 4 patch 3

The Structural Products development team is pleased to announce the availability of RAM Structural System CONNECT Edition Update 4 patch 3 (17.04.03.05). This software provides you a complete solution for analysis, design, drafting, and documentation for steel and concrete buildings, foundations, and even individual structural components; all in compliance with your local building codes.

RAM Structural System CE Update 4 patch 3 (17.04.03.05) Release Notes - Date: January 2023
This version corrects some significant errors, described below. We know errors are disruptive, we apologize for any inconvenience this may cause.

iTWIN / ISM
CONCRETE BEAM REINFORCEMENT EXPORT: Concrete beam reinforcement would not be exported when creating a new iTwin/ISM Repository.
Effect: Repository would be created but would be missing all concrete beam reinforcement information.
Frame - Analysis
LOADS ON TWO-WAY SLABS FROM TRANSFER WALLS*: The program ignored the loads on transfer gravity walls supported by two-way decks.
Effect: Point loads and line loads on transfer gravity walls were not applied to two-way decks on which the gravity walls were supported.
CRASH DURING ANALYSIS: The program may have crashed if Eigenvalue and a Response
Spectra load case are analyzed together when no other load cases are selected, for models with frame walls.
Effect: Program crash.
PANEL ZONE ELEMENTS: The program failed to insert user-assigned panel zone elements if a panel zone element was assigned to both strong and weak axis direction of a column. If only strong or only weak axis direction assignment was done, the program would successfully addthe panel zone element.
Effect: Panel Zone elements could not be assigned to both axes of a column. The program produced a warning message indicating that it failed to insert the panel zone elements.
Concrete - Column
EUROCODE CONCRETE COLUMN SLENDERNESS DETERMINATION*: The determination of the C coefficient used in the determination of lamda-lim may have been incorrect. EN 1992-1-1 Section 5.8.3.1 states that the value of C is 0.7 for members braced against sidesway when the moment from the analysis is less than the eccentric moment. This would be the case, for example, when the moment from the analysis is 0.0. It also states that the value of C is 0.7 for members not braced against sidesway. The program did not apply these requirements.
Effect: Potentially incorrect determination of whether or not a column was Slender

Download